Features
LogTemp program can be used for viewing and saving of several 1-Wire temperature sensors measurements. The interval of the measurements can be adjusted.
Measurements will be shown in day/week/month graphics. These pictures can be saved automatically using defined intervals. Last measurement values can also be saved to html-file. MySQL™ database could also be used for saving the measurements.
LogTemp program can be localized to other languages very easily. All program captions, messages etc. are read from the external lng-file. Default installation installs english.lng and finnish.lng files to the program directory. Other translations can be done by using the english.lng as a reference file.
If you want to log temperatures with Windows native service, see DS18x Service.
More LogTemp pictures:
- Program settings
- Sensor properties
- Messages
- Setting for saving
- Temperature settings
- Setting for graphics
- Humidity sensor setup
- FTP setup
- SMTP Server setup
- MySQL setup
- Day picture
- Week picture
- Month picture
- Daily Energy Consumption
- last.htm file
LogTemp requirements
- Operating system Windows 95 / 98 / ME / NT / 2000 / XP / Vista / 7
- Only x86 systems, although x64 with 32-bit 1-Wire drivers has been reported to work
- MicroLAN (1-Wire) adapter connected to the computer
- TMEX drivers, i.e. TMEX runtime environment or new 1-wire drivers
- Works only with 32-bit drivers
- Supported 1-wire sensors
1-wire sensors / chips supported by LogTemp
- DS1820 temperature sensors
- Measuring -50°C - +70°C
- Resolution 0,1°C, accuracy in practice ±0,5°C
- Better accuracy if calibration is used
- DS18B20, DS1822 and DS1920 temperature sensors
- DS2438
- Relative humidity measurements
- DS2438 + HIH-3610/4000/4010. Example here
- Hobby Boards model
- Solar Radiation measurements
- DS2438 + photodiode. Example here
- Hobby Boards model
- Barometer
- DS2438 + MPX4115A
- Hobby Boards model (B1-R1-A)
- Voltage
- VAD measurements (0 - 10 V)
- Relative humidity measurements
- DS2423 Counter
- Lightning and General Purpose counters
- Rain gauge
- Wind Speed
- Energy Consumption (kWh) with graphs
- No picture generated from the other values (yet)
- DS2405 and DS2406 Switch
- Alarm event can e.g. control relay board
- DS2406 has one (TO92 package) or two (TSOC package) channels to be used and in general it's more reliable than DS2405
- DS2409
- DS2409 based hubs based are supported
- DS2760
- Temperature measurements using type E, J, K, R, S or T thermocouples
- UV Index Meter
- Hobby Boards special UV Index Meter with 1-Wire interface
- Not recommended due to serious design failures of the meter. Poor temperature compensation and missing CRC protection. Not usable below +10°C temperatures
Donate
If you like see new versions of the LogTemp software, you may assist this by making a voluntary donation via Paypal. Button below will guide you to secure PayPal site for making donation. Thank you for your invaluable support.
Download
- The latest LogTemp setup Setup.exe (1018 kt).
- 1-Wire drivers: 1-Wire®/iButton® Drivers for Windows
- Other LogTemp language files here
Version history
- Version 2.25.0.97 21 Aug 2011
- xAP messages withdrawn
- Corrected Min/Max values when Fahrenheit is set
- Corrected settings for counter (DS2423) properties
- Corrected DS276x reading in Windows 7 environment
- Corrected DS2438 reading for combined sensors (e.g. Hum+Sun) when another sensor fails
- Corrected CSV-file columns compared to header line
- Setup form redesigned
- Changed FTP timer to compatible with other timers (x times measuring interval)
- Check your FTP timer now
- Added timer for MySQL. If used, measurements will cached until timer event, then sent all
- Added TIMEZONE_BIAS_UTC to XML-file, difference between UTC and Local time
- Added TemperatureGroups (three) for temperature measurements. Each group has own graphs
- Minor adjustments
- Earlier version history see this
Would it be possible to ad support for the DS2413 Dual Channel Switch? Thanks -Rob